Cooler type | Remote |
Condenser type | Heat exchanger -Glycol cooled |
Product coils | 10 -with JG and Oetiker marks (OD 9,5mm (3/8")) |
Coil length | 10x12m |
Compressor | 2 x Embraco NEU6212U (9,99cm³) |
Refrigerant | R290 |
Refrigerant filling quantity | 2x145g |
Required min. room space for cooler (m³) | 13,13 |
Ice bank size | 25kg |
Water Bath | 57L |
Circulations pump | Xylem 24m lift |
Supply voltage | 230/50Hz |
Thermostat type | Electronical thermostat 2HP Relay |
Cooling power | 1334W (At 24°C surrounding temperature, evaporating temperature -10°C, condensing temperature 55°C) |
Emitted Condenser Heat | 2500W |
Max. Current, A | 8,55 |
Cooling capacity 1st hour | 348L/h at inlet temp 14°C and outlet temp 4°C, 174L/h at inlet temp 24°C and outlet temp 4°C |
Continuing capacity | 126L/h at inlet temp 14°C and outlet temp 4°C, 63L/h at inlet temp 24°C and outlet temp 4°C |
Weight | 88kg |
Dimensions Cooler (WxDxHmm) | 586x657x984mm |
Power Cable | 3m, Schuko plug |
Recommended Maximum Pythonlength | 100m |
Run, A | 8 |
Power consumption, kW | 1,52 |
Eng. Cons. 24h, kWh | 9,85 (Energy consumption is mesured without any heat load) |
db | 61 |
R290, gr | 2x105 |
GWP | 3 |
Total EQ. CO2, tonns | 0,00063 |
Comment | All data based on ambient temp. of 24 degrees |